Komatsu — H- 22 Excessive shock when stopping swing ( one direction only)

TESTING AND ADJUSTING H-22, H-23 H-22 Excessive shock when stopping swing (one direction only) H-23 Excessive abnormal noise when stopping swing 20-231 1 YES Does control valve spool move smoothly? NO Cause Remedy Defective PPC valve Defective operation of control valve spool. Replace Correct or replace YES 1 Does condition become normal when YES safety valve is 2 replaced? Does condition become normal when NO suction valve is 3 YES cleaned? Is dirt found in swing machinery? NO NO Cause Remedy Defective swing motor safety valve Defective swing motor suction valve Defective swing machinery Defective back pressure valve. Replace Replace Repair or replace Repair or replace