Komatsu — H- 25 Swing speed is faster than specified swing speed

TESTING AND ADJUSTING ACTION TAKEN BY MONITOR PANEL WHEN ABNORMALITY OCCURS AND PROBLEMS IN MACHINE 20-238 User code Service code Abnormal system Nature of abnormality - E112 AE112 Short circuit in wiper motor drive normal rotation system. 1. Internal short circuit, short circuit with chassis ground in wiper motor. 2. Internal short circuit, short circuit with chassis ground in relay box. 3. Short circuit with chassis ground, short circuit in wiring harness between monitor P02 (11) and relay box W08 (2), or between W08 (6) and wiper motor W04 (3). - E113 AE113 Short circuit in wiper motor drive reverse rotation system. 1.

Internal short circuit, short circuit with chassis ground in wiper motor. 2. Internal short circuit, short circuit with chassis ground in relay box. 3. Short circuit with chassis ground, short circuit in wiring harness between monitor P02 (3) and relay box W08 (3), or between W08 (7) and wiper motor W04 (1). - E114 SE114 Short circuit in window washer drive system. 1. Internal short circuit, short circuit with chassis ground in washer motor. 2. Internal short circuit, short circuit with chassis ground in relay box. 3. Short circuit with power source in wiring harness between monitor P02 (2) (10) and relay box W08 (17), or between W08 (16) and M28 (1).