Komatsu — M- 12 When starting switch is turned ON ( engine stopped), caution items, emergency items flash ( battery, engine oil pressure lamps do not light up).

TESTING AND ADJUSTING TROUBLESHOOTING M-12 M-12 When starting switch is turned ON (engine stopped), caution items, emergency items flash (battery, engine oil pressure lamps do not light up). # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. # Check both the alternator system and the engine oil pressure system. M-12 a) Related electric circuit diagram 20-254 a) Alternator system. 3 YES Does monitoring YES code 43 show a 2 value of greater than 100? YES Is voltage between • Start engine and run NO C03 (female) (12) at mid-range speed 1 and chassis normal? or above.

• Set to monitoring Is voltage between • • D Tuis rc no sn tan re tc int gC s0 w3 i. tch code 43. alternator terminal R ON. NO and chassis normal? • Max. 1V. • Disconnect terminal R. • Turn starting switch NO ON. • Max. 1V. Cause Remedy Defective governor, pump controller Defective monitor panel Short circuit with power source in wiring harness between C03 (female) (12) - E08 (2) - alternator D Defective alternator. Replace Replace Repair or replace Replace