TESTING AND ADJUSTING TROUBLESHOOTING M-21, M-22 M-21 Swing lock switch is turned ON (LOCK ) but (swing lock monitor) does not light up. # Carry out this troubleshooting only of the swing lock is actually being actuated. # Before carrying out troubleshooting, check that all the re- M-21 Related electric circuit diagram. Table H14 (S10) M-22 Swing prolix switch is turned ON (prolix), but (swing lock monitor) does not flash. # Carry out this troubleshooting only of the swing prolix is actually being actuated. # Before carrying out troubleshooting, check that all the re- lated connectors are properly inserted. # Always connect any disconnected connectors before go- ing on the next step.
2 YES Defective monitor panel. Replace YES 1 Is bit (6) of monitoring code 21 lighted up? Is voltage between C17 (8) and chassis as shown in table? Turn starting switch up. Set to monitoring code 21. NO Defective governor, pump controller. Replace Turn starting switch ON. NO Defective contact or disconnection in wiring harness between C17 (female) (8) and prolix switch (4). Repair or replace M-22 Related electric circuit diagram Table H14 (S10) 20-263 lated connectors are properly inserted. # Always connect any disconnected connectors before go- ing on the next step. 1 YES Is voltage between P05 and chassis as shown in table? • Turn starting switch NO ON.
Cause Remedy Defective monitor panel. Defective contact or disconnection in wiring harness between P01 (female) (5) - X01 (4) - X05 (male). Replace Repair or replace Swing lock switch ON Max. 1 V Swing lock switch OFF 20 - 30V Cause Remedy Swing prolix switch ON Max. 1 V Swing prolix switch OFF 20 - 30V