Komatsu — INSTALLATION OF SOLENOID VALVE ASSEMBLY

DISASSEMBLY AND ASSEMBLY SOLENOID VALVE REMOVAL OF SOLENOID VALVE ASSEMBLY Disconnect the cable from the negative (-) terminal of the battery. 1. Open R.H. side cover. Remove PPC pumpless valve (1). 2. Remove valve bracket (2). 3. Remove 5 solenoid wiring connectors (3) from clip, then disconnect. # Mark the male and female ends of each connec- tor with tags to prevent mistakes when connect- ing. 4. Disconnect 10 hoses (4). # Fit tags on the hoses. 5. Remove mounting bolts, then remove solenoid valve assembly (5). When removing solenoid valve as an individual part: Remove mounting nut (6), then remove solenoid valve (7).

1 INSTALLATION OF SOLENOID VALVE ASSEMBLY Carry out installation in the reverse order to removal. 1 Mounting nut (6): 5-8 Nm (0.5-0.8 kgm). Solenoid valve (7) (individual part): 39.2 ± 9.8 Nm (4 ± 1 kgm). 30-94