Komatsu — INSTALLATION OF GOVERNOR, PUMP CONTROLLER ASSEMBLY

DISASSEMBLY AND ASSEMBLY PUMP CONTROLLER REMOVAL OF GOVERNOR, PUMP CONTROLLER ASSEMBLY Disconnect the cable from the negative (-) terminal of the battery. 1. Remove radio (2) if fitted. 2. Remove plate (1), then remove cover (3). 3. Lift cover (3) away carefully to locate speaker harness connector. Disconnect and remove panel completely. 4. Remove divider board (5). 5. Remove heater / air conditioner duct (5). 6. Disconnect 3 wiring connectors (6), then remove gov- ernor and pump controller assembly (7). INSTALLATION OF GOVERNOR, PUMP CONTROLLER ASSEMBLY Carry out installation in the reverse order to removal. Check the performance of the work equipment, travel, and swing.

For details, see TESTING AND ADJUST- ING. 1 30-131