Komatsu — FIXED THROTTLE VALVE

STRUCTURE AND FUNCTION HYDRAULIC PUMP When pump pressure PP is small, spool (3) is on the left. At this point, port C and port D are connected, and the pressure entering the LS valve becomes drain pressure PT . If port E and port G of the LS valve are connected (see (1) LS valve), the pressure entering the large diam- eter end of the piston from port J becomes drain pressure PT , and servo piston (9) moves to the right. In this way, the pump discharge amount moves in the direction of increase. As servo piston (9) moves further, piston (7) is moved to the right by slider (8). Springs (4) and (6) expand and the spring force becomes weaker.

When spring force becomes weaker, spool (3) moves to the right, so the connection between port C and port D is cut, and the pump discharge pressure ports B and C are con- nected. As a result, the pressure at port C rises, and the pressure at the large diameter end of the piston also rises, so the movement of piston (9) to the right is stopped. In other words, the stop position for piston (9) (= pump discharge amount) is decided at the point where the force of springs (4) and (6) and the push- ing force from the PC-EPC valve solenoid and the pushing force created by pressure PP acting on spool (3) are in balance. 10-51