STRUCTURE AND FUNCTION CLSS 1) Unload valve Function 1. When the control valve is at neutral, pump discharge amount Q discharged by the minimum swash plate angle is released to the tank circuit. When this happens, pump discharge pressure PP is set at 2.45 MPa (25 kg/cm 2 ) by spring (3) inside the valve. (LS pressure P LS : 0 MPa (0 kg/cm 2 )) Operation When control valve is at neutral Pump discharge pressure Pp is acting on the left end of spool (4), and LS pressure P LS is act- ing on the right end. When the control valve is at neutral, LS pres- sure P LS is 0, so only pump discharge pressure PP has any effect, and Pp is set only by the load of spring (3).

As pump discharge pressure Pp rises and reaches the load of spring (3) (2.45 MPa 25 kg/ cm 2 )), spool (4) is moved to the right in the di- rection of the arrow. Pump discharge pressure Pp then passes through the drill hole in sleeve (2) and is connected to tank circuit T . In this way, pump discharge pressure Pp is set to 2.45 MPa (25 kg/cm 2 ) 1. Unload valve 2. Sleeve 3. Spring 4. Spool Pp : Pump circuit (pressure) P LS :LS circuit (pressure) T : Tank circuit (pressure) 10-72