. MAINTENANCE SERVICE PROCEDURE WARNING distilled water, see 1. Stop the engine. 2. Loosen radiator cap (1) slightly to release the air, then remove the cap. 3. Prepare a container to catch the coolant, then open drain valve (2) at the radiator left lower portion and drain plug (3) at the side of the cylinder block to drain the coolant. 4. After draining the water, close drain valve (2) and plug (3), and fill with city water. 5. When the radiator is full, start the engine, and run it at low idle. Keep the engine running at low idle for 10 minutes until the water temperature reaches more than 90 ° C (194 ° F). 6.
After flushing, stop the engine, open drain valve (2) and plug (3), then close it again after all the water has drained out. 7. Add coolant through the water filler port up to the mouth of the port. For details of the COOLANT density, see "COOLANT DENSITY TABLE". 8. To remove the air contained in the coolant, run the engine at low idle for 5 minutes, then run for a another 5 minutes at high idle. (When doing this, leave the water filler cap OFF.) 9. Stop the engine. About 3 minutes later, supply city water up to the water filler, then close radiator cap. 4 - 29 COOLANT is toxic.
When open the drain valve, be careful not to get coola If it gets in your eyes, flush your e yes with large amount of fresh water an When changing the coolant or whe n handling the coolant containing COOLANT that has been drained durin g repair of radiator, please contact your Komatsu distr ibutor or request a specialist company to carry out the operation. COOL ANT is toxic. Do not let it flow into drainage ditches or COOLANT is already diluted wit h distilled water, so it is not flammable. (For details of the di "COOLANT AND WATER FOR DILUTION (PAGE 4-7)").
Check the density with a COOLANT te Prepare a container that is a larg er than the specified amount of coolant, then drain the coolant i Prepare a hose to use when fillin g with coolant.