Yamaha Exciter II-570 — Electrical Starting System

_________________ E_LE_C_T_R_IC_A_L_S_TA_R_T_IN_G __ SV_S_T_E __ M IELECliiil 3 2 Inspection 1. Inspect: Commutator (outer surface) Dirty --+ Clean with #600 grit sandpaper CD. Hold the armature in a vise ® and copper or aluminium plate ®. Lightly grip the armature with a vise. 2. Measure: Commutator (diameter) Measurethe diameter ® of the commutator at points where the brush comes in contact. Out of specification --+ Replace. Commutator wear limit ® : 27 mm (1.06 in) ---:r® 3. Measure: • Mica CD (insulation depth) (between commutator segments) Outofspecification --+ Scrape micato proper limits. Use a hacksaw blade ® that is ground to fit. Mica undercut ®: 0.4 .. 0.8 mm (0.016 .. 0.03 in) 4.

Measure: • Armature coil resistance (insulation/continuity) Defect(s) --+ Replace starter motor. Inspecting steps: • Connect the pocket tester for the continuity check CD and the insulation check ®. • Measure the armature coil resistances. ~ Armature coil resistance: Continuity check CD: 0.016.0 ± 6% at 20°C (68°F) Insulation check ®: More than 100 k.o at 20· C (68·F) • If the resistance is incorrect, replace the starter motor. 8-10 http://ReadManuals.com