Yamaha Exciter II-570 — Electrical

BATTERY INSPECTION I ~r I §it I BATTERY INSPECTION (for EX570ER)) 1. Remove: • Protector plate (battery) CD 2. Inspect: • Battery fluid level Fluid level should be between upperCD and lower ® level marks. Incorrect --. Refill. Refill with distilled water only; tap water contains minerals harmful to a battery. 3. Check: ----\> • Specific gravity Less than 1.280 --. Recharge battery. Charging current: 1.6 amps/10 hrs Specific gravity: 1.280 at 20'C (68'F) 367003 Replace the battery if: • Battery voltage will not rise to a specific value or bubbles fail to rise even after many hours of charging.

• Sulfation of one or more cells occurs, as indicated by the plates turning white, or an accumulation of material exists in the bottom ofthe cell. • Specific gravity readings after a long, slow charge indicate one cell to be lower than the rest. • Warpage or buckling of plates or insulators is evident. Always charge a new battery before using it to ensure maximum performance. 2-28 http://ReadManuals.com