Komatsu — CLEANING THE COOLING SYSTEM

MAINTENANCE CLEANING THE COOLING SYSTEM Immediately after stopping the engine, the engine coolant is HOT and the pressure inside the radiator is high. Removing the cap and draining the water under this condition could cause burns. Allow the engine to cool down, then turn the cap slowly to release the pressure. Start the engine and flush the system. When standing up or leaving the operator's seat, set the shift lever to the N position and set the parking brake switch to the PARKING position. For details of starting the engine, see “PRECAUTIONS BEFORE STARTING WORK OPERATIONS” on page 2-78 and “STOPPING THE ENGINE” on page 2-89.

When the undercover is removed, there is danger of touching the fan. Never go to the rear of the machine when the engine is running. Stop the machine on level ground when cleaning or changing the coolant. Clean the inside of the cooling system, change the coolant, and replace the corrosion resistor according to the table below. Super Coolant (AF-ACL) has an anti-corrosion effect as well as an antifreeze effect. The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30 % by volume is necessary.

When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below. It is actually better to estimate a temperature about 10є C (50є F) lower when deciding the mixing rate. Mixing rate of water and antifreeze 3-30 WA480-5L Type of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze (All-season type) Every year (autumn) or every 2000 hours, whichever comes first Every 1, 000 hours and when cleaning the inside of the cooling system and when changing coolant.

Non-permanent type antifreeze containing ethylene glycol (winter, one season type) Every 6 months (spring, autumn) (Drain antifreeze in spring, add antifreeze in autumn). When not using antifreeze Every 6 months or every 1000 hours, whichever comes first Min. atmospheric temperature ° C -10 -15 -20 -25 -30 ° F 14 5 -4 -13 -22 Amount of antifreeze Liters 15.0 17.5 20 22.5 25.0 US gal 3.96 4.62 5.28 5.94 6.61 Amount of water Liters 35.0 32.5 30.0 27.5 25.0 US gal 9.25 8.59 7.93 7.27 6.60