Komatsu — SUBTRACTION FUNCTION

13. Input the load on the target load input screen. The data for the pre- viously calculated load is displayed on the input screen.The cursor is at the 100 ton position. The following explains the procedure when inputting 7.5 tons as the target when the previous load (the load set in Step 7) is 7.1 tons. OPTIONS, ATTACHMENTS 14. “0” is displayed at the 100 ton position, so leave it at “0” and press the ( ‘ ) of monitor panel selector switch 1 twice. “00” is selected and the cursor moves to the 1 ton position. 15. “7” is already displayed at the 1 ton position, so press the ( ‘ ) of monitor panel mode selector switch 1. “7” is selected and the cursor moves to the 0.1 ton position. 16.

“1” is displayed at the 0.1 ton position, so press the (>) or ( monitor panel mode selector switch 2 to select “5”, the press the ( ‘ ) of monitor panel mode selector switch 1. “.5” is selected and 7.5 tons is set as the target load. 17. Press the ( ‘ ) of monitor panel mode selector switch 1. If the monitor accepts the setting, the buzzer gives short sounds, and the setting of the loaded calibration is completed. The screen returns to the normal service meter and time display. SUBTRACTION FUNCTION The following explanation assumes that after setting the remain mode, the target load is 12 tons as shown in the diagram on the right and that B is selected as the type of material. WA480-5L 5-15