Komatsu — PERFORMING CALIBRATION (ADJUSTING 0 POINT) WHEN LOADED

OPTIONS, ATTACHMENTS 5. Press the (>) or ( bottom line changes to “LOAD BUCKET”, so press the ( ‘ ) of monitor panel selector switch 1. 6. Press the ( ‘ ) of monitor panel selector switch 1. The display changes to “STEP 1" on the top line, and “FULLY ROLL BACK” and “AT CARRY POSI” are displayed in turn for 3 seconds each on the bottom line. 7. Load the bucket with a load of a known amount, then follow the instructions on the screen, tilt the bucket back fully, and lower the lift arm to set to the travel posture. 8. When the lift arm is lowered, the display changes to “STEP 2" and “RAISE TO TOP”. This completes preparation for setting the calibration when loaded. 9.

Follow the instructions on the screen and raise the lift arm fully. When raising the lift arm, perform the operation as close to actual operation as possible. 10. When the setting of the loaded calibration is completed correctly, the buzzer gives short sounds, and the screen changes to the screen for inputting the target load. 11. If the setting of the loaded calibration is not completed correctly, the buzzer gives a long sound, and the display returns to “CALIBRATION” on the top line and “LOAD BUCKET” on the bottom line. 12. Repeat the procedure again from Step 6. 5-14 WA480-5L