9. When the setting of the empty calibration is completed correctly, the buzzer gives short sounds, and the character display returns to the normal service meter and time display. OPTIONS, ATTACHMENTS 10. If the setting of the empty calibration is not completed correctly, the buzzer gives a long sound, and the display returns to “CALIBRATION” on the top line and “EMPTY BUCKET” on the bottom line. 11. Repeat the procedure again from Step 5. PERFORMING CALIBRATION (ADJUSTING 0 POINT) WHEN LOADED Remark Normally, there is no need to perform calibration when loaded. It is enough to perform calibration when empty, so perform calibration when loaded only if greater accuracy is required. 1.
Check that the normal service meter and time are displayed on the character display. 2. Press the ( ‘ ) of monitor panel selector switch 1 and display “LOAD METER”. 3. Press the ( ‘ ) of monitor panel selector switch 1, then press the (>) or ( BRATION”. 4. Press the ( ‘ ) of monitor panel selector switch 1. “EMPTY BUCKET” is displayed on the bottom line. WA480-5L 5-13