OPTIONS, ATTACHMENTS PERFORMING CALIBRATION (ADJUSTING 0 POINT) WHEN EMPTY 1. Check that the normal service meter and time are displayed on the character display. 2. Press the ( ‘ ) of monitor panel selector switch 1 and display “LOAD METER”. 3. Press the ( ‘ ) of monitor panel selector switch 1, then press the (>) or ( “CALIBRATION”. 4. Press the ( ‘ ) of monitor panel selector switch 1. “EMPTY BUCKET” is displayed on the bottom line. 5. Press the ( ‘ ) of monitor panel selector switch 1. The display changes to “STEP 1" on the top line, and “FULLY ROLL BACK” and “AT CARRY POSI” are displayed in turn for 3 seconds each on the bottom line. 6.
Follow the instructions on the screen, tilt the empty bucket back fully, then lower the lift arm to set to the travel posture. 7. When the lift arm is lowered, the display changes to “STEP 2" and “RAISE TO TOP”. This completes preparation for setting the calibration when empty. 8. Follow the instructions on the screen and raise the lift arm fully. When raising the lift arm, perform the operation as close to actual operation as possible. 5-12 WA480-5L