Komatsu — REVERSE/FORWARD INDICATOR LAMPS

OPTIONS, ATTACHMENTS MODE SELECTOR SWITCH This switch is used to select automatic or manual change of the direction of rotation of the cooling fan AUTO: The direction of the fan can change automatically, this is controlled with a timer MANUAL: The direction of the fan is controlled manually Remark If an immediate reversal of the fan is needed, select this MANUAL mode. FORWARD/REVERSE TIMER Set this timer with the ignition switch in the “OFF” position This timer is used to set the forward and reverse revolution time of the cooling fan. The cooling fan repeats the directional changes when the selector switch is set in the AUTO position.

REVERSE/FORWARD INDICATOR LAMPS Remark Reverse direction is only for removing debris from the surface of the radiator core, always operate machine in the forward mode. REVERSE: This orange timer lamp lights up while the system is in the reverse cycle FORWARD: This green timer lamp lights up while the cooling fan is in the forward (normal operation) mode 5-26 WA480-5L