Komatsu — REVERSE SETTING KNOB

FORWARD SETTING KNOB OPTIONS, ATTACHMENTS This knob is used to set the forward rotation time of the cooling fan If outer larger knob (5) is turned, the green pointer moves. Set the pointer to the desired time with the knob first If the time unit is set to h , and the scale to 3 and the green pointer to 0.5, the fan will revolve in the forward direction continuously for 1/2 hour. Normally set the forward revolution time to 1/2 hour. Shorten the time if the radiator core surface is blocked more often than normal.

If the forward setting knob (5) (green pointer) is set to 1/2 hour and the reverse setting knob (6) (orange pointer) is set to 15 seconds and then the cycle is initiated, the cooling fan starts revolving forward. After the fan revolves forward for 1/2 hour it then revolves in reverse for 15 seconds, then revolves forward for 1/2 hour and in reverse for 15 seconds again. If the ignition switch is turned off, the timer is reset. If the ignition switch is turned on again, the cooling fan starts revolving forward again and repeats the above cycle. Remark Before changing direction, the fan is allowed to slow (coast) for 8 seconds. This action lowers the impact caused by the change in direction.

When the engine is started, there will be an 8 second delay before the cooling fan starts rotation. This is normal When the cooling fan FORWARD/REVERSE switch is switched, there will be an 8 second delay before the cooling fan starts rotation. This is also normal REVERSE SETTING KNOB This knob is used to set the reverse direction of the cooling fan If inner smaller knob (6) is turned, the orange pointer moves. Set the pointer to a desired time with this knob. If the time unit is set to 10s, the scale figure to 3 and the orange pointer to 1.5, the cooling fan will revolve in reverse for 15 seconds continu- ously. Normally, set the reverse revolution time to 15 seconds.

If the reverse time is set too long, then overheating may result. WA480-5L 5-27