Komatsu — SETTING GREASING TIME IN COLD AREAS

OPTIONS, ATTACHMENTS PILOT LAMP DISPLAY ON MACHINE MONITOR The display of pilot lamp (2) on the machine monitor lights up or flashes according to the following conditions. Lighted up : Normal operation1 flash per sec: Grease cartridge empty 1 flash per 0.5 sec: Defective decompression, pump pressurized, pres- sure detected, fuse blown SETTING GREASE TIME The set time and greasing frequency limit differs according to the opera- tion condition and greasing plan for the machine, so set the following items to carry out suitable centralized greasing. Greasing interval (Hr.): Greasing interval for automatic operation Greasing time (min):

Length of time pump is operated for each greasing operation Greasing frequency limit (times): No of times for operating pump before the 1000 cc cartridge becomes empty. The settings when shipped from the factory are as follows. Greasing interval: 3 hours Greasing time: 7 minutes Greasing frequency limit: 100 times The grease level alarm is set to sound after 300 hours on the hourmeter (when normal operation). Remark Be careful since the life of grease cartridge will be shortened if the greasing interval becomes shorter. Also if the greasing interval becomes shorter, the amount of grease dripping from the tip of the machine increases. It may make the machine and surrounding area dirty.

SETTING GREASING TIME IN COLD AREAS In cold temperatures, the viscosity of the grease rises, so it is necessary to increase the grease time. For example, if the machine is used at temperature below -20 degrees, set the greasing time to 20 minutes (code No 7). In addition, use the lithium-based grease No. 0. When changing the set value, please consult your Komatsu dealer. WA480-5L 5-43