Komatsu — TROUBLESHOOTING

OPTIONS, ATTACHMENTS PRECAUTIONS WHEN HANDLING AUTO GREASING SYSTEM Basically, the power source input to the lubrication controller should be DC24V, but use a max of 30V. The grease nipple installed to the service port used for initial charging of the divider valve has a ball check structure, so it may leak if it gets stuck in it. Check it from time to time, and replace the grease nipple immediately if any grease is leak- ing. When carrying out initial operation or when the grease tank is empty, air may get into the piston portion of the pump. If the pressure does not rise within the specified time when running the pump, and an error is displayed for the controller, bleed the air.

i the divider valve or grease piping are removed when replacing the attachment on the machine, handle carefully to pre- vent any damage. When storing or installing again, be extremely careful to prevent the entry of any air or dirt. If there is air in the system, bleed immediately. TROUBLESHOOTING If any abnormality occurs in the greasing system, the error codes will flash alternately to display the type of abnormality. WA480-5L 5-47