MAINTENANCE 12 Add hydraulic oil through oil filler port (F) to the specified level, then install cap. For details of the oil to use and refill capacity see "20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. 13 Check that the hydraulic oil is at the standard level. See “EVERY 100 HOUR SERVICE”. 14 Run the engine at low idle and extend and retract the steering, bucket and lift arm cylinders 4 - 5 times.
Be careful not to operate the cylinder to the end of its stroke (stop approximately 100 mm (3.94 in) before the end of the stroke) WARNING If the engine is run immediately at high speed or the cylinder is operated to the end of its stroke, the air inside the cylinder could cause damage to the piston packing. 15. Next, operate the steering, bucket, and lift arm cylinders to end their stroke 3-4 times, then turn OFF the engine and loosen bleed plug (8). Then run the engine at low idle to bleed the air from the hydraulic tank. After bleeding the air, turn OFF the engine and tighten plug (8) again. 16 Check the hydraulic oil level and add oil to the specified level.
For details, see "24.5 EVERY 100 HOURS SERVICE". 17 Next, increase the engine speed and repeat the procedure in Step 15 to bleed air. Continue this procedure until no more air comes out from plug (8). 18 tighten plug (8) and Torque to: 11.3 ± 1.5 N C m (1.15 ± kgm, 8.3 ± 1.1 lbf ft) 19 Check that the hydraulic oil is at the standard level. For details, see "24.5 EVERY 100 HOURS SERVICE". 20 Check to be sure, there are no oil leaks at the filter cover mount. 24.8.5 ADJUST ENGINE VALVE LASH CLEARANCE After the first 1000 hours only thereafter evey 2000 hour intervals. For detail procedures to adjust valve lash clearance refer to the”EVERY 2000 HOURS SERVICE”. 3-60