Komatsu — 3.17.1 CENTRAL LUBRICATION SYSTEM ”CLS”

OPERATION 3.17 OPERATION OF THE LUBRICATION SYSTEM ADJUSTMENTS OF THE CENTRAL LUBRICATION SYSTEM The following adjustments can be made in the service menu of the VHMS system, under menu point 4.8.1: Level 4: Service Menu / Settings 4.8.1 *PAUSE TIME *MONITORING TIME *PRESSURE RELIEF TIME *LUBE CYCLE COUNTER Refer to Service Manual VHMS system for description of adjust- ment procedure. Repairs on the Central Lubrication System with the Engine running or with the Engine OFF and Main Switch Key in ON position If repairs under the above conditions have been carried out it is necessary to reset the control circuit of the lubrication system by actuating the rotary switch (1), illust.

(Z25567) for a full lube cycle. If this manually actuated lube cycle is not being carried out, the fault message ”LUBE SYSTEM FAILURE” will remain on the health monitor (3). Resetting of the lube system control circuit can also be done by shutting down the engine and switching OFF the main switch key. NOTICE For more information regarding inspection, trouble shooting and maintenance of the lubrication system, refer to the sepa- rate manual LUBRICATION SYSTEMS in volume 2 binder. 219