3.17 OPERATION OF THE LUBRICATION SYSTEM OPERATION 3.17 OPERATION OF THE LUBRICATION SYSTEM 3.17.1 CENTRAL LUBRICATION SYSTEM ”CLS” The central lubrication system works automatically as soon as the engine is running at high idle speed. The VHMS System monitors the function of the central lubrication system. Trouble conditions of the lubrication system are indicated through fault messages on health monitor (3).
Legend for illustration Z25567 (1) Switch, manual actuation of central lubrication sys- tem (2) Switch, manual actuation of slew ring gear lubrica- tion system (3) Health monitor Manual actuation of the central lubrication system Manual actuation of the lubrication system overrides the adjusted pause time (factory setting 15 minutes). The lubrication cycle starts after a pressure build up time of 1 to 2 minutes. Thereafter the monitoring time of 10 minutes starts. The complete lubrication cycle takes approximately 12 minutes. After this period the lubri- cation cycle counter adds one lubrication cycle to the memory.
For display of the cycle counter reading use the service menu of the VHMS system. REMARK The start of a manually actuated lubrication cycle can be delayed by up to 10 minutes if the system is in the monitoring time period of a previous automatic lubrication cycle. If the central lubrication system fails to work for a period longer than four hours an automatic bucket motion cut off can happen depending on the installed VHMS soft ware. Repair the system as soon as possible. 218 CAUTION CAUTION