Komatsu — 3.2.10 ENGINE OIL MANAGEMENT SYSTEM

OPERATION 3.2 CONSTRUCTION OF THE SHOVEL Engine Oil Management System The engine oil management system combines the automatic engine oil supply system Reserve and the oil burning system Centinel in connection with the Eliminator oil filtration system. REMARK On machines destined for Australia, the Centinel system is made inoperative for legal reasons. The oil change intervals are reduced accordingly, see maintenance section for more informa- tion. Reserve System Oil Flow Schematic, illustration Z25458 (1) Reserve oil tank (2) Oil level sight gauge. Check oil level in the reserve tank before starting the engine.

If necessary refill reserve tank via service arm adapter, refer to page 238 for more information. (3) Pumping unit, located on the side member of the power frame. The pump unit works automatically as soon as the engine speed is above 300 RPM. The pump unit consists of a pumping element for feeding oil from tank (1) into the engine oil pan via lines (6), oil filters (4) and line (7). The second pumping ele- ment withdraws oil from the engine oil pan and feeds it back into the reserve tank via line (8 and 9) when the oil level in the oil pan exceeds the maximum run- ning oil level. This function maintains a favorable engine oil level.

The combined operation of the pumping elements provides constant circulation of oil between the engine sump and reserve tank (1) increasing the total volume of working oil. This main- tains the oil quality over longer periods. Oil drawn off by the Centinel burn system is also replaced through the supply system "Reserve". (4) Oil filter of the supply system. Replace both filter ele- ments after every 400 - 500 operating hours.

(5) Crankcase breather filter (6) Suction lines (7) Oil supply line from pump (3) to engine oil pan (8) Withdrawal oil line from oil pan to pump (3) (9) Oil feed-back line to reserve tank (1) (10) Reserve tank breather filter (11) Oil drain plug (12) Power frame side member 75