Intake air pre-heater The temperature switch (8) in the circuit diagram is attached to the front of the engine. It is closed when cold, and in this status the glow plugs can be put into operation. When the coolant temperature reaches 40 - 50 _ C (105 - 120 _ F) the temperature switch (8) opens and pre-heating stops. If the temperature switch (8) is defective, e.g. always open, pre-glowing is not possible. If the temperature switch does not open, the glow plugs remain switched on for a maximum of 14 to 15 minutes. The pre-heating procedure is then stopped by the electronic control unit (7).
Checking the glow plugs If the glow plugs (9 in circuit diagram) are to be checked, the temperature switch (8) must be bridged. This leaves approx. 14 minutes in which to check the glow plugs. The glow plugs are checked with a voltmeter. 9 If a voltage of 12 V is present at a glow plug, this glow plug is in order. If the voltage present is 24 V, the glow plug is defective and must be changed. + 0 V V 9 9 9 V 12 V, glow plug in order 24 V, glow plug defective 9 9 9 12 V, glow plug in order V V 159