Transmitters Checking the coolant temperature transmitter by measuring the resistance 300 Ω 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 110 120 _ C Dip temperature sensor up to the lower edge of the hex section into a mixture of water and 30 % anti− freeze/anti−corrosion agent. The liquid must be circulated during this measurement. Check the temperature with a thermometer as the liquid is heated. Measure the resistance and compare it with the calibrated curves ( _ F = 1.8 _ C + 32). Curve 1: Temperature transmitter for 1 electrical instrument Curve 2:
Temperature transmitter for 2 electrical instruments Temperature transmitter for 1 electrical instrument: checking values and tolerance of transmitter resistance Temperature transmitter for 2 electrical instruments: checking values and tolerance of transmitter resistance 160 1 2 Temperature _C 40 60 90 100 Resistance Ω 296.0 134.0 51.2 38.5 Tolerance − ± 13.5 Ω = ± 4_C ± 4.3 Ω = ± 3_C ± 3.0 Ω = ± 3_C Temperature _C 60 90 100 Resistance Ω 67 25.60 19.25 Tolerance ± 6.5 Ω = ± 4_C ± 2.1 Ω = ± 3_C ± 1.5 Ω = ± 3_C