Checking and repairing pipe cluster for heat exchanger D Remove pipe cluster, see page 63 Fig. 1 When the pipe cluster is removed, we recommend always checking the position of the deflectors (ar- rows) (the picture shows the pipe cluster for a D 2848 LE 403 engine). Displaced deflectors may reduce the flow of cool- ant, which in turn leads to an increase in coolant temperature. 1 Fig. 2 Measure the position of the deflectors. Use the pipe-cluster side with the collar (arrow) as refer- ence edge (this side can be recognised as that end of the pipe cluster with the larger diameter). 2 Fig.
3 The nominal distances between the deflectors on pipe clusters for D 2858 LE 403 / 405 and D 2840 LE 403 engine: A 207 B 400 C 593 A B C 3 Fig. 4 The nominal distances between the deflectors on pipe clusters for D 2848 LE 404 engines: A 111 B 207,5 C 304 D 394,5 E 497 F 593,5 G 690 A B C D E F G 4 68