MAN — Cleaning heat exchanger pipe cluster

Cleaning heat exchanger pipe cluster Internal cleaning of the pipe cluster in raw water heat exchangers Deposits may form on the sea-water side of the pipe cluster in the heat exchanger, impairing the heat transition to such an extent that the coolant heat can no longer be sufficiently conducted away. This is bound to cause an increase in the coolant temperature. In the event of an increase in coolant temperature, check all other components of the cooling system first.

D Raw-water filter contaminated D Raw-water inlet clogged up D Flow rate of raw water sufficient D Impeller of raw−water pump worn If all components of the cooling system are in order, but the coolant temperature remains nevertheless high, cleaning the pipe cluster may eliminate the fault. Proceed as follows: D Lay or stand removed pipe cluster in a suitable container made of synthetic material such as PE, PP, PVC, GRP etc. D Fill container with undiluted genuine pickling liquid at room temperature (Lithsolventsдure or engine pickling fluid RB-06) until the pipe cluster is completely submerged. D Allow pickling fluid to soak in for approx. 10 hours.

If this period of time is not sufficient, allow another 5 hours. D The pickling period can be shortened by heating up the pickling fluid up to a maximum of 50 _ C (120 _ F) and by moving the pipe cluster from time to time. D After the pickling the pipe cluster is to be intensively rinsed with tap water and again installed in the heat exchanger. D Use new seals (O-ring seals) for the caps. D Install pipe set and check heat exchanger for leaks. Waste water conditioning With the aid of soda lye the drained and used cleaning and pickling fluid is conditioned to a pH value of 7.5 to 8.5. After the sediments have settled the clear fluid above can be drained into the sewerage system.

The sludge is to be taken to a dump for special waste. 70