Starter/Starter BENCH TEST SOLENOID DRIVE STARTER NOTE: Perform bench test before disassembling the starter motor to determine the cause of the problem. IMPORTANT: Never operate motor longer than 20 seconds. Allow at least two minutes for cooling and battery recovery before operating again. Overheating, caused by excessive operation, will seriously damage starting motor. 1. Connect a 12-volt battery (A) to starter battery terminal (B) and starter frame (C). Use heavy duty cables. 2. Connect a remote start switch (D) between switch terminal (E) and battery terminal (B). M37149 -UN-29AUG88 NOTE:
A short piece of wire with a small clip on the end will allow a more positive connection at the switch terminal. A—12-Volt Battery B—Battery Terminal C—Starter Frame D—Remote Start Switch E—Switch Terminal M98,2060K,30 -19-05NOV85 CTM2 (19APR90) 60-14 16, 18, 20 & 24HP Onan Engines AllTractorManuals.com 130495 When switch is activated, starter should engage and run. IF SOLENOID CHATTERS; hold-in winding is open-circuited. IF NOTHING HAPPENS; either the solenoid pull-in winding is open-circuited or mechanical parts are sticking. IF SOLENOID ENGAGES, BUT MOTOR DOES NOT RUN; check solenoid switch continuity, brushes, armature, and field windings. Solenoid cannot be repaired, replace it.
M98,2060K,31 -19-26NOV85 60 14