Komatsu — 36.3 SWITCHING MONITOR SCREEN

36. HANDLING MULTI MONITORING SYSTEM 5) When using the displays in the remaining value display portion 1 and load weight display portion 2 to adjust the load in the bucket when loading the dump truck and an amount in excess of the target production is loaded, print out the data. If the amount remaining inside the bucket is not necessary and is thrown away, press the cancel switch on the bucket control lever. Remaining value display portion 1 will change to the target production. The data can be canceled using the cancel switch only while the weight of the load in the bucket is being displayed in load weight display portion 2 (approx. 15 seconds).

6) If an amount exceeding the production amount has been loaded, and the boom is raised with the load still in the bucket without printing out the data, this action will be taken as an abnormality, and “---” will flash in load weight display portion 2 , and the buzzer will sound intermittently. In this condition, the measurement is not carried out, so press the figures, sub-total switch and load meter switch at the same time for at least 2 seconds to display the target production in remaining value display portion 1 and 0 tons in load weight display portion 2 . In this condition, raise the boom again. 7) Two types of output mode can be selected for printing out the load meter. Mode A:

Each individual weighed load is printed out. Mode B: Only the sub-total load and total number of loads are printed out. For details of the method of switching between mode A and mode B, see “36.3.5 OPERATION RECORD MODE”. An example of the load meter print out is shown below. 5-79