36. HANDLING MULTI MONITORING SYSTEM When the display in remaining value display portion 1 shows 0 tons or a value close to this, the loading to the target value is completed, so press the figures, sub-total switch or the bucket control lever sub-total switch for at least 2 sec- onds and print out. When a load exceeding the target production has been loaded The value in remaining value display portion 1 is shown in red with a – mark. The weight of the excess is displayed and the buzzer sounds intermittently. Any load beyond this is not measured. Press the figures, sub-total switch or the bucket control lever sub-total switch for at least 2 seconds and print out.
4) When using the displays in the remaining value display portion 1 and load weight display portion 2 to adjust the load in the bucket when loading the dump truck, and an amount in excess of the target production is loaded, if there is any load remaining in the bucket when the data is printed out, it can be loaded as it is into the next dump truck. Remaining value display portion 1 is displayed with the amount remaining in the bucket subtracted from the target production, and the amount remaining in the bucket is displayed for 15 seconds in load weight display portion 2 . This is recorded as the 1st bucket load for the next dump truck, so load it as it is into the next dump truck.
The following operation is also possible as long as the target production is not changed. Continuous work such as loading 2 and a half loads into one dump truck, loading the remaining half into the next dump truck, and then loading a further 2 loads. 5-78