Komatsu — 37.3 METHOD OF OPERATING AUTO-LEVELING, REMOTE POSITIONER

37. HANDLING AUTO-LEVELING, REMOTE POSITIONER 37.3 METHOD OF OPERATING AUTO-LEVELING, REMOTE POSITIONER 37.3.1 METHOD OF OPERATING AUTO-LEVELING 1. When auto mode switch 1 is pressed, the system is turned ON, pilot lamp 2 lights up, and the auto- leveling system is actuated. 2. Operate the bucket to the desired dumping angle, then stop and press level set up switch 3 . Pilot lamp 4 will flash for 2.5 seconds to complete the setting. REMARK Dumping angle θ can be set within a range of +15° and –30° from the horizontal position of the bucket. If the pilot lamp does not flash, the setting is outside the above angle, so operate to the desired angle again.

Once the angle is set, it is kept in memory until it is set again. 3. When the level set up switch is pressed, the system is turned OFF and the pilot lamp goes out. 4. When the auto mode switch is pressed, the system is turned OFF, the pilot lamp goes out, and the system changes to the normal leveler condition. 5-103