37. HANDLING AUTO-LEVELING, REMOTE POSITIONER 37.3.2 METHOD OF OPERATING REMOTE POSITIONER When UP/DOWN selector switch 1 is pressed, the system is turned ON, pilot lamp 2 lights up, and the remote positioner is actuated. REMARK Each time the UP/DOWN selector switch is pressed, the lighting of the UP and DOWN lamp changes. (UP lighted up DOWN lighted up UP/DOWN both lighted up go out) 2. Raise the lift arm to the desired height (above horizontal), then stop it and keep position set up switch 3 pressed. Pilot lamp 4 will flash for 2.5 seconds and the setting is completed.
REMARK Actuate the remote positioner, raise the lift arm to the desired height, and set the position with the position set up switch. Once the UP position is set, it is kept in memory until it is set again. However, the DOWN position is fixed as the carrying position. 3. When the UP/DOWN selector set switch is pressed, the system is turned OFF and the pilot lamp goes out. 4. When the UP/DOWN selector switch is pressed, the system is turned OFF, the pilot lamp goes out, and the system changes to the normal positioner condition. 5-104