Maintenance section Coolant Water Antifreeze Hard water, or water with high levels of calcium and magnesium ions, encourages the formation of insoluble chemical compounds by combining with cooling system additives such as silicates and phosphates. The tendency of silicates and phosphates to pre- cipitate out-of-solution increases with increasing water hardness. Hard water, or water with high lev- els of calcium and magnesium ions encourages the formation of insoluble chemicals, especially after a number of heating and cooling cycles. DOOSAN prefers the use of distilled water or deionized water to reduce the potential and severi- ty of chemical insolubility. Make proper antifreeze additions.
Adding pure antifreeze as a makeup solution for cooling system top-up is an unacceptable practice. It increases the concentration of antifreeze in the cooling system which increase the concentration of dissolved solids and undissolved chemical inhibitors in the cooling system. Add antifreeze mixed with water to the same freeze protection as your cooling system. Use the chart below to assist in determining the concentration of antifreeze to use. ppm = parts per million Using water that meets the minimum acceptable water requirement may not prevent drop-out of these chemical compounds totally, but should mini- mize the rate to acceptable levels.
99 Antifreeze Concentrations Protection Temperature Concentration Protection to -15°C (5°F) 30% antifreeze and 70% water Protection to -23°C (-10°F) 40% antifreeze and 60% water Protection to -37°C (-34°F) 50% antifreeze and 50% water Protection to -51°C (-60°F) 60% antifreeze and 40% water MINIMUM ACCEPTABLE WATER Water Content Limits gr/gal(ppm) Chlorides (Cl) 2.4(40) maximum Sulfates (SO ) 4 5.9(100) maximum Total hardness 10(170) maximum Total solids 20(340) maximum PH 5.5 to 9.0