Scania — Overview of flash codes for coordinator

Engine Ch 1 page 40 SHOP MANUAL MT41 - 12.2004 Code Description of fault Cause Action Note 22 The supply voltage is too high. The supply voltage exceeds 35 volts for more than 2 seconds. Check the alternator. Certain inputs and outputs become inactive. The coordinator may suffer damage. 23 The supply voltage is too low. The supply voltage is less than 18 volts for more than 2 seconds. Check the battery and alternator. Certain inputs and outputs become inactive. 24 The supply voltage is too low. The supply voltage is less than 18 volts for more than 2 seconds. Check the battery and alternator. Certain inputs and outputs become inactive.

25 Check value from End of line (EOL) is incorrect 26 Road speed sensor signal missing or faulty. 27 The signal from the RCB (remote Control Box) switches are implausible. 28 Incorrect signals from the droop-settings switches 29 Faulty remote start switch or short circuit 31 No communication from the slave-coordinator or the master coordinator. 32 Short circuit in the signal cable to the coolant temperature warrning lamp 33 Short circuit in the signal cable to the charge indicator lamp 34 Incorrect signal from the Fixed speed switches 35 Fault in CAN communication