MAN — Man Series 40 Engine Operator's Guide

HOW-TO SECTION If a pre-diluted, fully formulated coolant is purchased, simply fill the cooling system. For best overall performance, a coolant consisting of 50% concentration of antifreeze (50% antifreeze, 50% water) is recommended . corrosion protection and is not recommended . See Figure 27 for ethylene glycol-base coolant concentration versus freezing and boiling temperatures. See Figure 28 for propylene glycol-base coolant concentration versus freezing and boiling temperatures. An antifreeze concentration over 67% (67% antifreeze, 33% water) is not recommended due to poor heat transfer, reduced freeze protection (IEG only), and possible silicate dropout.

An antifreeze concentration below 33% (33% antifreeze, 67% water) offers too little freeze and/or Always verify that the freeze point and nitrite concentration of the antifreeze/water mixture are correct by using a POWER Trac ® 3–Way Coolant Test Strip. If chemical analysis is used, elements in the coolant must fall within the limits listed in Table 25.

Table 25 Fully Formulated Glycol Coolant Limits with TMC RP-329, TMC RP-330 Chemistry Type A (50/50 Coolant/Water Mixture) Recycled Antifreeze — Antifreeze or coolant recycled by reverse osmosis, distillation, and ion exchange, properly re-inhibited to meet TMC RP-329 Type A or TMC RP-330 Type A requirements, has been demonstrated to provide service equivalent to virgin antifreeze. Recycled antifreeze or coolants of these types are preferred. Other recycled coolants, especially coolants recycled through filtration processes, are not recommended . 92 All information subject to change without notice. (Rev.

May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION Fully Formulated Glycol Coolant Concentration Limits Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 200 – 3200 PPM Silicon 50 – 250 PPM Phosphorous 0 PPM pH 8.0 – 11.0