MAN — Man Series 40 Engine Operator's Guide

HOW-TO SECTION Table 26 Power Cool 3000 Concentration Limits (5% Power Cool 3000/ 95% Water) Power Cool 3000 SCA inhibitors should be mixed at 5% by volume with water. This is 1 quart per 5 gallons of water. These additions can be made by adding liquid SCAs available in a variety of sizes. Coolant filters are also available for different cooling system capacities. These filters release the proper amount of SCA at initial fill. or de-ionized water which eliminates the adverse effects of minerals in tap water is preferred. High levels of dissolved chlorides, sulfates, magnesium, and calcium in some tap water causes scale deposits and/or corrosion.

These deposits have been shown to result in water pump failures and poor heat transfer, resulting in overheating. If tap water is used, the mineral content in the water must be below the maximum allowable limits listed in Table 27. Water Requirements Distilled, reverse osmosis-purified, Table 27 Satisfactory Water Limits – Make-Up Water Only 94 All information subject to change without notice. (Rev.

May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION Power Cool 3000 Coolant Concentration Limits Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 0 – 1000 PPM Silicon 50 – 250 PPM Phosphorous 0 PPM pH 8.0 – 11.0 Maximum Allowable Parts per Million Grains per Gallon Chlorides 40 2.5 Sulfates 100 5.8 Total Dissolved Solids 340 20 Total Hardness – Magnesium and Calcium 170 10