MAN — Man Series 40 Engine Operator's Guide

HOW-TO SECTION specifications. Always maintain coolant at the proper level. drained, thoroughly cleaned, and refilled. 10. Coolant Life: OAT Coolants require the addition of an extender at 300,000 miles (480,000 km), two (2) years, or 5,000 hours, whichever comes first. Use 1 pint of extender for every 20 gallons of coolant. Glycol Coolant. A properly maintained cooling system, filled with phosphate-free coolant consisting of a 50/50 mix of antifreeze and water per TMC RP-329 “Type (EG) or TMC RP-330 “Type A” (PG) specifications can be operated to the limits recommended.

The proper maintenance involves periodic evaluation using Power Trac 3-Way Coolant Test Strips and the addition of SCA as needed, indicated by the strip test. To verify coolant acceptability, submit a sample for coolant analysis every 300,000 miles (480,000 km), three (3) years, or 5,000 operating hours, whichever comes first. Submit the sample in a DDC Power Trac Coolant Test Bottle. Required part numbers are listed in Table 55. Other Coolants. Other properly maintained coolants may be operated up to 250,000 miles (480,000 km), two (2) years, or 4,000 operating hours, whichever comes first. At this time the system must be completely drained, thoroughly cleaned, and refilled. 11.

Do not use the following in engine cooling systems: Soluble oil High silicate, automotive-type antifreeze Chromate SCAs Methoxy propanol-base coolant OAT Coolant. A properly maintained OAT coolant may be operated 600,000 miles (960,000 km), four (4) years, or until overhaul, whichever comes first. At this time the system must be completely Methyl alcohol-base coolant Sealer additives or coolant containing sealer additives. HVAC coolant Phosphated coolants 104 All information subject to change without notice. (Rev. May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION