LUBRICATION AND PREVENTIVE MAINTENANCE INTERVALS Item 5 Turbocharger, Air-to-Air Charge Cooler NOTE: If lack of engine performance is noted after high-mileage operation, the turbocharger wastegate should be checked for proper operation. Authorized Detroit Diesel distributors have the trained personnel and are properly equipped to perform this service. To avoid injury from hot surfaces, allow engine to cool before removing any component. Wear protective gloves. Item 6 Battery Visually inspect the turbocharger mountings, intake and exhaust ducting and connections for leaks daily. Check the lube oil inlet and outlet lines for leaks or restrictions to oil flow.
Check for unusual noise or vibration and, if excessive, stop the engine and do not operate until the cause is determined. To avoid injury from accidental engine startup while servicing the engine, disconnect/disable the starting system. Periodically inspect the charge air cooler (if used) for buildup of dirt, mud, etc. and wash off. Check the charge cooler, ductwork, and flexible connections for leaks and have repaired or replaced, as required. Check the hydrometer of maintenance-free batteries for charge. See Figure 14. If lead-acid or low-maintenance batteries are used, check the specific gravity of each cell every 150 operating hours.
Check more frequently in warm weather due to the more rapid loss of water through evaporation. Check turbocharger heat-insulating exhaust system blankets (if used) for damage on a daily basis. Torn, matted, crushed, oil-soaked or otherwise damaged insulation blankets must be replaced immediately. Wastegated Turbochargers – The turbocharger wastegate actuator is factory-calibrated and is not adjustable. 60 All information subject to change without notice. (Rev. May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION