HOW-TO SECTION to prevent the engine from starting. To avoid cover or vent cap damage, do not use tools to tighten the vent cap. NOTICE: [b] Operate the manual primer pump on the filter header until the primer pump is hard to depress. See Figure 25. [c] Crank the engine three times for 15 seconds each. Reapply the primer pump after each crank cycle. NOTICE: Do not allow the fuel level in the see-thru cover to fall below the top of the collar, since this may lead to interruption of the fuel flow and engine stalling. [d] Once the primer pump is hard to depress (usually three crank and hand prime cycles), reconnect the CMP. 2.

Start the engine and allow the lubrication system to reach its normal operating pressure, then increase engine speed to high idle for 2 to 3 minutes. After the air is purged and with the engine still running, loosen the vent cap on the filter cover. the fuel level in the cover will start falling. When the fuel level falls to the top of the collar on the Fuel Pro cover, tighten the vent cap quickly by hand . NOTICE: To avoid starter damage, do not crank the engine longer than 15 seconds at a time. Allow a 15-second starter cool down interval between starting attempts. 5. Start the engine and check for leaks. Fuel Pro Filters — Use the following procedure for an engine with Fuel Pro filters. 1.

Remove the vent cap from the top of the filter by turning counter-clockwise. Fill the cover full of clean fuel. After making sure the O-ring seal is installed on the vent plug, reinstall the plug and tighten by hand only. NOTE: If the engine fails to start after replacement of fuel filters, the fuel system will require priming with tool J 5956 or equivalent. Authorized Detroit Diesel distributors are properly equipped to perform this service. 88 All information subject to change without notice. (Rev. May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION