. MAINTENANCE SERVICE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING *: Permanent type antifreeze shall meet the requirements of ASTM D3306-03. Stop the machine on level ground when cleaning or changing the coolant. The coolant has the important function of preventing corrosion as well as preventing freezing. Even in the areas where freezing is not an issue, the use of antifreeze coolant is essential. Komatsu machines are supplied with Komatsu Supercoolant (AF-NAC). Komatsu Supercoolant (AF-NAC) has excellent anticorrosion, antifreeze and cooling properties and can be used continuously for 2 years or 4000 hours. Komatsu Supercoolant (AF-NAC) is strongly recommended wherever available.
To maintain the anticorrosion properties of Supercoolant (AF-NAC), always keep the density of Supercoolant between 30% and 68%. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing table given below. It is actually better to estimate and temperature about 10 ° C (18 ° F) lower when deciding the mixing ratio. The mixing ratio depends on the ambient temperature, but it should always be a minimum of 30% by volume (antifreeze/total amount of coolant x 100). The freezing temperature of undiluted antifreeze is -15 ° C (5 ° F). Do not store undiluted antifreeze at a temperature of below -15 ° C (5 ° F).
Mixing rate of water and antifreeze 4 - 20 Immedi ately after th e engine is stopped, the e ngine co olant is hot and the p ressure inside t he radiator i s high. Removing t he cap and draining the water under this conditio n could c ause burns. Allow th e engine to cool down, then t urn the cap slowly to release the pressure . Start th e engine and flush the sy stem. Before standing up or leavin g the ope rator's seat, set the work equipment loc k lever to the LOC K position. For det ails of startin g the engine , see "CHECK BEFOR E STARTING ENGINE , ADJUST (PAG E 3-69)" and "STARTING ENGINE (PAGE 3-85)" in the OPERATION section of the Operati on and Maintenance Manual.
When t he undercove r is remove d, there i s dange r of to uching the f an. Never e nter the rear of the machine when the engine is running. Clean the inside of th e cooling s ystem, c hange the c oolant and replace the corrosion resistor according to t he table below. I Antifreeze coolant nterval of cleaning inside of cooling system and changing antifreeze coolant Replacing corrosion resistor Komatsu supercoolant (AF-NAC) Every two years or every 4000 hours whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant. Permanent type antifreeze (All-season type, *) Every year (autumn) or every 2000 hours whichever comes first. Min.
atmospheric temperature °C °F Above -10 -15 -20 -25 -30 Above 14 5 -4 -13 -22 Amount of antifreez Liters e US gal 5.10 6.12 6.97 7.82 8.50 1.35 1.62 1.84 2.07 2.25