Miscellaneous—Operational Checkout Pilot Shut-Off Valve Checks (Continued) T7351CB —UN—22AUG90 Move pilot shut-off lever to UNLOCKED (forward) .position. Operate all dig and travel functions. YES: Go to next check. Do all functions operate? NO: Go to your authorized dealer. VD76477,0000057 -19-12SEP12-11/27 Travel Alarm And Travel Alarm Cancel Switch Checks T141257 —UN—12APR01 1— Travel Alarm Cancel Switch Pilot shut-off lever in UNLOCKED position (forward). Push travel pedals or levers forward or pull travel pedals or levers rearward. Does travel alarm sound? Push travel pedals or levers and allow travel alarm to operate for a minimum of 15 seconds.
While continuing travel, push travel alarm cancel switch (1). YES: Go to next check. Does travel alarm stop sounding? NO: Check fuse 5 in fuse box. Go to your authorized dealer. VD76477,0000057 -19-12SEP12-12/27 Pilot Controller Pattern Check Engine at slow idle. Operate machine in clear area. Move pilot shut-off lever to UNLOCKED position. Slowly move hydraulic levers to all positions on decals. Do bucket, boom, arm, and swing move as decals show? YES: Go to next test. (See Section 2-2 for more detailed information.) NO: Install decals for pattern (operator preference). Go to your authorized dealer. Continued on next page VD76477,0000057 -19-12SEP12-13/27 4-3-7 060313 PN=149