SECTION 5 MAINTENANCE Page 52 TRANSMISSION SYSTEM 5.18.4. CLEANING THE TRANSMISSION SUCTION STRAINER The location of the suction strainer is shown in Fig. 5.43. 1. The transmission should be drained as described under Par. 5.18.2. Install the drain plug. 2. Disconnect tube (1, Fig. 5.45) from elbow (2), then loosen bolts (3), remove retainer (4) with strainer assembly (6) from the transmission housing, and remove gasket (5). 3. Thoroughly clean the gasket material from the transmission housing and retainer (4). 4. Unscrew strainer assembly (6) from retainer (4). Look inside the strainer and inspect the valve spring for breakage. Replace, if necessary. 5.
Wash the parts in a commercial cleaning solvent. Remove all particles from the magnetic rods on the strainer (if there are such particles). If necessary, the rods can be removed. Dry all parts thoroughly. 6. Install strainer assembly (6) into retainer (4) and apply a new gasket (5) to the retainer. Install this assembly into the transmission housing. Thread elbow (2) into retainer (4) and tighten. Attach tube (1) to the elbow. 7. Fill the transmission with oil (Refer to Par. 5.18.2). Fig. 5.45. Transmission Oil Suction Strainer 1. Tube 2. Elbow 3. Bolts 4. Retainer 5. Gasket 6. Strainer Assembly 5.18.5. SERVICING THE BREATHER 1.
Remove the breather located on the RH side of a machine (Refer to Fig. 5.46). 2. Wash the breather in a commercial cleaning solvent to completely remove any sediment in the cap. WARNING! Wear eye protection when using air or water under pressure to clean parts. Limit air pressure to 200 [kPa] and water pressure to 270 [kPa]. 3. Dry the breather thoroughly using compressed air. If compressed air is not available, shake to remove the excess cleaning solvent. 4. Dip the cap in clean engine oil. Allow the excess oil to run out. 5. Reinstall the breather. OM515C520C99/1E DRESSTA