Komatsu — 6.12. TORQUE VALUES FOR SPLIT FLANGE CONNECTIONS

SECTION 6 SPECIFICATIONS Page 36 TORQUE VALUES FOR STANDARD ENGLISH FASTENERS Chart 2 6.12. TORQUE VALUES FOR SPLIT FLANGE CONNECTIONS The following chart 3 provides the tightening torques for split flange connections used in hydraulic systems. Split flanges and fitting shoulders should fit squarely. Install all bolts, finger tighten and then torque evenly. Overtorquing bolts will damage the flanges and/or bolts, which may cause leakage. Chart 3 * ) Inside diameter of hydraulic tube or hose fitting.

OM515C520C99/1E DRESSTA Nominal Thread Diameter [inch] Standard Torque ±10% [Nm] 1/4 10 5/16 21 3/8 38 7/16 60 1/2 92 9/16 130 5/8 180 3/4 325 7/8 520 1 780 1 - 1/8 1110 1 - 1/4 1565 1 - 3/8 2050 1 - 1/2 2720 1 - 3/4 3380 2 5080 Bolt size in inches Flange size in inches* Torque Value [Nm] 1/2 5/16 20 – 24 3/4 3/8 30 – 37 1 3/8 37 – 47 1 – 1/4 7/16 47 – 61 1 – 1/2 1/ 2 62 – 79 2 1/ 2 75 – 88 2 – 1/2 1/ 2 107 – 123 3 5/8 187 – 203 3 – 1/2 5/8 159 – 180