Komatsu — 6.14. TORQUE VALUES FOR HOSE CLAMPS

SPECIFICATIONS SECTION 6 Page 37 6.13. TORQUE VALUES FOR HYDRAULIC TUBES AND FITTINGS Chart 4 Above torque figures are recommended for plain, cadmium or zinc plated fittings, dry or wet installations. These torques are not recommended for tube with wall thickness of 0.89 [mm] or less 6.14. TORQUE VALUES FOR HOSE CLAMPS The following chart 5 provides the tightening torques for hose clamps used in all rubber applications: radiator, air cleaner, operating lever boots, hydraulic system, etc.). Chart 5 DRESSTA OM515C520C99/1E Size Tubing O.D.

in inches Thread size in inches Torque values for 37 [°] flared fittings [Nm] Torque values for O-ring boss plugs, locknuts and 37 [°] flared fittings [Nm] 4 1/4 7/16 – 20 12 – 16 8 – 14 5 5/16 1/ 2 – 20 16 – 20 14 – 20 6 3/8 9/16 – 18 29 – 33 20 – 27 8 1/2 3/ 4 – 16 47 – 54 34 – 41 10 5/8 7/8 – 14 72 – 79 47 – 54 12 3/4 1 – 1/16 – 12 104 – 111 81 – 95 14 7/8 1 – 3/16 – 12 122 – 138 95 – 109 16 1 1 – 5/16 – 12 149 – 163 108 – 122 20 1 – 1/4 1 – 5/8 – 12 190 – 204 129 – 156 24 1 – 1/2 2 – 7/8 – 12 217 – 237 163 – 190 32 2 2 – 1/2 – 12 305 – 325 339 – 407 CLAMP TYPE AND SIZE TORQUE ± 0.6 [Nm] Radiator, Air Cleaner, Boots, etc [Nm] Hydraulic System, [Nm] "T" Bolt (any diameter) 6.2 – 7.3 ----------- Worm Drive - 1-3/4 in.

Open Diameter & Under 2.2 – 3.3 4.5 – 5.6 Worm Drive - Over 1-3/4 in. Open Diameter 4.5 – 5.6 ----------- Worm Drive - Al1 "Ultra-tite" 10.7 – 11.8 4.5 – 5.6