Implement Management System Operating Implement Management System (IMS) CAUTION: Avoid possible injury and loss of tractor control. A stored high gear in a learned sequence could initiate rapid shift changes when activating IMS. Clear IMS sequence after application is completed. (See CLEARING IMS SEQUENCE in this section.) A B RXA0082723 —UN—26JUL05 Accidental use of IMS could cause unexpected tractor or implement movement. NOTE: Press IMS ON/OFF switch to OFF, then ON to view the functions programmed in the two sequences. A—ON/OFF Switch B—LEARN/SAVE Switch 1. Make sure tractor is moving with speed of at least 0.5 km/h (0.31 mph). Press ON/OFF switch (A). 2. Press LEARN/SAVE switch (B).
OURX935,0000277 1921MAR061/2 3. Press SEQUENCE 1 or SEQUENCE 2 switch (A). Indicator light (B) will show the sequence being learned (1 or 2) and an audible signal will sound. Learn Mode has a 60 second time limit and will stop recording events when time limit is reached. Should timeout occur, limit or reduce the number of steps recorded for a sequence so they are completed within the time limit, or use both sequences 1 and 2 to record a complete series of events that exceeds the time limit of a single sequence (60 seconds). RXA0056431 —UN—29AUG01 NOTE: Depressing clutch pedal during learn mode allows several functions to be performed at the same time. CommandARM 4.
Perform desired functions. 5. Press LEARN/SAVE switch to store functions and end learning mode. Sequence number indicator will stop flashing. IMS indicator light (C) will remain on. C MPH km/h NOTE: Depressing clutch pedal during a sequence will suspend the remaining functions until clutch pedal is released. RXA0085777 —UN—09JAN06 A IMS 2 1 6. Press desired sequence switch and the sequence of learned events will begin. When sequence concludes, sequence number (B) will no longer be displayed. B Corner Post Display A—Sequence Switch B—Sequence Indicator C—IMS Indicator OURX935,0000277 1921MAR062/2 456 122208 PN=118