1500 Hour Service Changing MFWD Differential Case Oil NOTE: The differential case for MFWD axle with Independent Link Suspension is connected to the transmission case and operates using the same oil. There is no fill location. 1. Put the tractor on level surface. RXA0052919 —UN—17APR01 2. Remove differential case drain plug (A). Replace plug after oil has drained. 3. For 1300 Axle, add John Deere HYGARD through fill hole (B) until oil is even with bottom of hole. Install the plug. For 1500 Axle, remove check plug (C), add John Deere HYGARD through fill hole (B) until oil is even with bottom of check hole. Install the fill and check plugs.
Differential Case Plug and Fill Hole (1300 Axle) Differential Case 1300 Axle Oil Capacity ....................................... 13.6 L (14.2 qt) RXA0087868 —UN—16MAR06 1500 Axle Oil Capacity ...................................... 18.7 L (19.74 qt) 4. After a few minutes of operation, recheck oil level. Add oil if necessary. 5. Tighten plugs. MFWD Drain Plugs—Specification Drain Plug—Torque ......................................................... 70 N∙m (52 lbft) Differential Case Plug and Fill Hole (1500 Axle) A—Drain Plug B—Fill Hole C—Check Plug OURX935,0000339 1919JUN081/1 1066 122208 PN=286