Komatsu — EVERY 250 HOURS SERVICE

EVERY 250 HOURS SERVICE 2. To adjust the belt tension, loosen bolts (I) and lock nut (31, and rotate adjusting bolt (2). 3. After adjustment, tighten bolts (I 1 and lock nut (3) securely. * After operating the machine for one hour with a newly exchanged V-belt, test and adjust the V-belt again. * When adjusting the V-belt, do not attempt to push the compres- sor directly with a bar or the like, but use a wood pad to prevent damage to the core. Sr Check each pulley for damage, and V-grooves and V-belt for wear. Particularly, check whether V-belt is in contact with bottom of V-groove through wear.

Sr Replace belt if it has stretched, leaving no allowance for adjust- ment, or if there is a cut or crack on belt. w-03730 - 99 -