PTO and Pump Electrical Controls 54.38 Troubleshooting Fire Pump Controls Function Electrical Diagnosis Test No. Test Procedure Test Result Action 1 In ServiceLink, use the Chassis Module (CHM) Configuration screen to determine which CHM solenoid output numbers control the two solenoids for the fire pump. Go to test no. 2. Then open the "AMU Solenoids Circuits" or "AAVA Solenoids Circuits" in the appropriate Datalink Monitor template. Yes Make sure the vehicle has full air pressure. Turn the ignition on. Perform the PTO and Fire Pump Control Switch and Interlocks Test in Table 3.
Attempt to engage the pump using the smart switch in the dash while observing the status of solenoid output under the "Outputs from BHM" heading for both of the solenoid numbers determined above. See Fig. 1 and Fig. 3. No Does the status of the solenoid output for both solenoids turn on at all? They may turn on, then drop out. 2 Using the appropriate solenoids Datalink Monitor template, enter Test Mode. Both operate Go to test no. 3. Attempt to turn the fire pump control solenoids on one at a time using the ON buttons on the template. Neither operate Go to test no. 5. Make sure one of the reference parameters in Table 5 is applied to the vehicle. If not, correct as necessary. NOTE:
When done, exit Test Mode. NOTE: If operating normally, one solenoid should exhaust air when turned on, the other will exhaust air when turned off. For the solenoid that is not working, make sure it is wired to the correct CHM output pins per the ServiceLink CHM Configuration screen. What happens when the solenoids are turned on? Check the solenoid output circuit from the CHM to the solenoid, including the solenoid coil ground circuit, for opens. Only one operates Check the solenoid output circuit between the CHM and solenoid for short to ground. This will cause the CHM solenoid output to shut off due to high current. The current draw must not exceed 0.85A. Check the solenoid.
See Section 42.19. If all of the above is OK, replace the CHM. Business Class M2 Workshop Manual, Supplement 22, September 2012 300/3