PTO and Pump Electrical Controls 54.38 Troubleshooting PTO Function Electrical Diagnosis Test No. Test Procedure Test Result Action 4 In ServiceLink, open the "PTO Interlocks" Datalink Monitor template. Yes Determine the cause for interlock drop out and repair as necessary. Using Table 4 , determine which PTO interlocks are used based on the PTO reference parameter programmed in to the BHM. Check PTO solenoid output circuit amperage. If it exceeds 0.85A, make necessary repair or modification. Engage the PTO using the switch in the dash. No Do any of the necessary interlocks drop out when the PTO solenoid drops out? If amperage is OK, check for mechanical problem.

5 In ServiceLink, open the "Chassis Module Battery Inputs" Datalink Monitor template. The problem may be in the PTO solenoid output circuit. Is Battery Power Feed No. 3 at approximately battery voltage? Make sure the PTO is wired to the correct CHM output pin per the ServiceLink CHM Configuration screen. Check PTO solenoid output circuit from the CHM to the solenoid, including the solenoid coil ground circuit, for opens. If CHM solenoid output circuit contains a relay, check the relay and the rest of its circuits to the solenoid. Yes Check the solenoid output circuit between the CHM and solenoid (or relay if equipped) for short to ground.

This will cause the CHM solenoid output to shut off due to high current. The current draw must not exceed 0.85A. Check the solenoid. See Section 42.19. If all of the above is OK, replace the CHM. Check fuse 13 in the power distribution module (PDM). If blown, locate and correct the source of high current. No If fuse 13 is OK, check wiring between PDM fuse 13 and CHM pin C4-J for open circuit. Table 1, PTO Function Electrical Diagnosis Business Class M2 Workshop Manual, Supplement 22, September 2012 300/2